CELANEX® 2300 GV3/20 10/0240
CELANEX® 2300 GV3/20 10/0242
CELANEX® 2300 GV3/20 10/9102
CELANEX® 2300 GV3/20 30/2155
CELANEX® 2300 GV3/20 30/2240
CELANEX® 2300 GV3/20 NATURAL
CELANEX 2300 GV3/20 | PBT | Glass Reinforced
Descript ion
Chemical abbreviation according to ISO 1043-1: PBT Moulding compound ISO 7792- PBT, MGHR, 08-040N, GB20
Polybutylene terephthalate, low warpage, 20 % glass beads. Flammability UL 94 HB minimum thickness 0.82 mm. Recognition by Underwriters Laboratories, USA (UL)
Other Processing
Injection Molding
Melt Temperature 260-270 ℃
Mold Temperature *) 75-85 ℃
Maximum Barrel Residence Time **) 5-10 min
Injection Speed fast
Peripheral screw speed max.0,3 m/sec
Back Pressure 10-30 bar
Injection Pressure 600-1000 bar
Holding Pressure 400-800 bar
Nozzle Design open design preferred
Injection speed, injection pressure and holding pressure have to be optimized to the individual article geometry. To avoid material degradation during processing low back pressure and minimum screw speed have to be used. Overheating of the material has to be avoided. For grades containing flame retardants, a maximum temperature of 265℃ should not be exceeded.
Ticona recommends only externally heated hot runner systems.
*) For moulded parts with especially high requirements to the surface quality or dimensional stability, a mold temperature of up to 110℃ can be advantageous.
**) If the cylinder temperatures are higher than the recommended maximum temperatures, the max. residence time in the barrel has to be reduced.
ISO Data | Physical properties | Value | Unit | Test Standard |
Phys | Density | 1450 | kg/m³ | ISO 1183 |
Melt volume rate (MVR) | 20 | cm³/10min | ISO 1133 | |
MVR test temperature | 250 | ℃ | ISO 1133 | |
MVR test load | 2.16 | kg | ISO 1133 | |
Humidity absorption (23℃/50%RH) | 0.2 | % | ISO 62 | |
Mech | Mechanical properties | Value | Unit | Test Standard |
Tensile modulus (1mm/min) | 3500 | MPa | ISO 527-2/1A | |
Tensile stress at break (5mm/min) | 50 | MPa | ISO 527-2/1A | |
Tensile strain at break (5mm/min) | 4 | % | ISO 527-2/1A | |
Tensile creep modulus (1h) | 3500 | MPa | ISO 899-1 | |
Tensile creep modulus (1000h) | 2400 | MPa | ISO 899-1 | |
Flexural strength (23℃) | 86 | MPa | ISO 178 | |
Charpy impact strength @ 23℃ | 34 | kJ/m² | ISO 179/1eU | |
Charpy impact strength @ -30℃ | 34 | kJ/m² | ISO 179/1eU | |
Charpy notched impact strength @ 23℃ | 3.5 | kJ/m² | ISO 179/1eA | |
Charpy notched impact strength @ -30℃ | 3.5 | kJ/m² | ISO 179/1eA | |
Therm | Thermal properties | Value | Unit | Test Standard |
Melting temperature (10℃/min) | 225 | ℃ | ISO 11357-1,-2,-3 | |
DTUL @ 1.8 MPa | 70 | ℃ | ISO 75-1/-2 | |
DTUL @ 0.45 MPa | 180 | ℃ | ISO 75-1/-2 | |
Vicat softening temperature B50 (50℃/h 50N) | 190 | ℃ | ISO 306 | |
Coeff.of linear therm. expansion (parallel) | 1.1 | E-4/℃ | ISO 11359-2 | |
Limiting oxygen index (LOI) | 21 | % | ISO 4589 | |
Flammability @1.6mm nom. thickn. | HB | class | UL94 | |
thickness tested (1.6) | 1.6 | mm | UL94 | |
UL recognition (1.6) | UL | - | UL94 | |
Flammability at thickness h | HB | class | UL94 | |
thickness tested (h) | 0.82 | mm | UL94 | |
UL recognition (h) | UL | - | UL94 | |
Elec | Electrical properties | Value | Unit | Test Standard |
Relative permittivity - 100 Hz | 4.4 | - | IEC 60250 | |
Relative permittivity - 1 MHz | 4.2 | - | IEC 60250 | |
Dissipation factor - 100 Hz | 85 | E-4 | IEC 60250 | |
Dissipation factor - 1 MHz | 180 | E-4 | IEC 60250 | |
Volume resistivity | >1E13 | Ohm*m | IEC 60093 | |
Surface resistivity | >1E15 | Ohm | IEC 60093 | |
Electric strength | 26 | kV/mm | IEC 60243-1 | |
Comparative tracking index CTI | 225 | - | IEC 60112 | |
SpecProd | Test specimen production | Value | Unit | Test Standard |
Processing conditions acc. ISO | 7792 | - | Internal | |
Injection molding melt temperature | 260 | ℃ | ISO 294 | |
Injection molding mold temperature | 80 | ℃ | ISO 294 | |
Injection molding flow front velocity | 200 | mm/s | ISO 294 | |
Injection molding hold pressure | 70 | MPa | ISO 294 |
Processing
Pre Drying
Necessary low maximum residual moisture content: 0.02%
CELANEX should in principle be predried. Because of the necessary low maximum residual moisture content the use of dry air dryers is recommended. The dew point should be =< - 30℃. The time between drying and processing should be as short as possible.
For subsequent storage of the material in the dryer until processed (<= 60 h) it is necessary to lower the temperature to 100℃.
Drying time (h):2-4
Drying temperature (℃):120 - 140